XLPE Cables

We are one of the prominent XLPE Cables Manufacturers in India. Our sole Objective is to provide the best XLPE Cable, Cross Linked Polyethene Cables, Insulated Armoured Power Cables, XLPE SWA PVC Cables, Underground High Voltage Cable, Industrial XLPE unarmored Cables, Electrical Specification Wires, etc. to the buyers. What’s more, all our Cables are economically priced too. As a result, we have garnered repute amid the prominent XLPE Cables Suppliers in India.

Cross Linked Polyethene Cables (XLPE)

  •  ►  Relemac Technologies Pvt. Ltd., pioneered the manufacture of Cross Linked Polyethylene (XLPE) Power Cables in India.
  •  ►  Dry Cured & Drycooled CCV Line with State-of-the-art extrusion process.
  •  ►  Design as per Indian and International Standards.
  •  ►  Approved by leading consultants.

Manufacturing & Dealing Range

  •  ►  1kV upto 33kV
  •  ►  Aluminium and Copper Conductors
  •  ►  Single Core Cables upto 1000 sqmm
  •  ►  Multi Core Cables upto 630 sqmm
  •  ►  FRLS Sheathed Cables
  •  ►  Aerial Bunched Cables
Single Core Copper/Aluminium Conductor XLPE Insulated PVC Sheathed Cables Unarmoured A2XY
Product Type KV Range
unscreened 3.3 KV
screened 3.8 / 6.6 KV
screened 6.36 / 11 kV
screened 11 / 11 kV
screened 12.7 / 22 kV
screened 19 / 33 kV

 

Single Core Copper/Aluminium Conductor XLPE Insulated PVC Sheathed Cables Round Wire Armoured A2XWaY
Product Type KV Range
unscreened 3.3 KV
screened 3.8 / 6.6 kV
screened 6.36 / 11 kV
screened 11 / 11 kV
screened 12.7 / 22 kV
screened 19 / 33 kV

 

Three Core Copper/Aluminium Conductor XLPE Insulated extended / taped PVC Inner Sheath Cables, Flat Strip Armoured A2XFY (P/T). Cables are available with both Taped(T) and extended PVC (P) inner sheath as per customer requirements.
Product Type KV Range
unscreened 3.3 KV
screened 3.8 / 6.6 kV
screened 6.36 / 11 kV
screened 11 / 11 kV
screened 12.7 / 22 kV
screened 12.7 / 22 kV
screened 19 / 33 kV

 

CURRENT RATINGS

Ratansiri. Recommendations for Current Ratings:

The Current rating of power cable is defined by the maximum intensity of current (amperes) which can flow continuously through the cable, under permanent loading conditions, without any risk of damaging the cable or deterioration of its electrical properties.

The value given in the tables are valid for one circuit in a three phase system under conditions specified. For grouping cables rating factors must be used.

The current carrying capacities mentioned in Ratansiri technical data are intended as a guide, to assist operating engineers in selecting cables for safety and reliability.

Basic assumptions and conditions of installation :-
• Max. Conductor Temperature : 90° C.
• Ambient Ground Temperature : 30° C.
• Ambient Air Temperature : 40° C.
• Thermal resistivity of soil : 150°C.Cm/W
• Depth of laying (to the highest point of the cables laid directly in the ground )
   3.3,6.6 & 1 IkV Cables : 90 cm
   22 and 33kV Cables : 105cm
• Max. Conductor Temperature for Short Circuit : 250° C.

 

To obtain the maximum current carrying capacity of a cable operating at different conditions from the standard, various rating factors are to be multiplied, as follows :-

I a = K x I s in amperes

Where ;

I a : Current rating at actual operating conditions (amperes)